Pipe Size - Valves
1 1/4 in
Center Line Pipe Center Size
5 1/2 in
Electrical Connections
1/2
Valve Design
2-Way/2-Position
Item
Fuel Gas Solenoid Valve
Valve Configuration
Normally Closed
Body Material - Valves
Aluminum
Valve Ways and Positions
2-Way/2-Position
Ambient Temp. Range
-40 Degrees to 77 Degrees F
Application
For On-Off Control of Fuel Gas in Commercial and Industrial Gas Burners
Seal Material - Valves
NBR
Coil Enclosure
General Purpose Junction Box and Watertight
NEMA Rating
1, 2, 3, 3S, 4, 4X
Environmental Rating - Valves
Indoor, Outdoor
Standards
UL and CSA for Safety Shutoff
Max. Operating Pressure Differential Water
5 psi
Min. Operating Pressure Differential
0 psi
Max. Operating Pressure Differential
5 psi
Max. Operating Pressure Differential Air/Inert Gas
5 psi
Max. Fluid Temp.
125 Degrees F
Operation Type
Pilot Operated
Operating Pressure Differential Fuel Gas - Minimum
Not Applicable
Operating Pressure Differential Natural Gas - Minimum
Not Applicable
Operating Pressure Differential Fuel Oil - Maximum
Not Applicable
Outlet Connection Type
NPTF
Operating Pressure Differential Air/Inert Gas - Minimum
Not Applicable
Operating Pressure Differential Light Oil - Maximum
Not Rated
Ambient Temperature - Maximum
140 Degrees F
Operating Pressure Differential Steam - Minimum
Not Applicable
Ambient Temperature - Minimum
-40 Degrees F
Operating Pressure Differential Hot Water - Maximum
Not Rated
Operating Pressure Differential Liquid CO2 - Maximum
Not Applicable
Operating Pressure Differential Fuel Gas - Maximum
Not Applicable
NEMA Enclosure Rating
1, 2, 3, 3S, 4, 4X
Valve Type
High Flow Gas Shut Off
Operating Pressure Differential Steam - Maximum
Not Rated
Operating Pressure Differential Light Oil - Minimum
Not Applicable
Actuator Type
Double Solenoid
Operating Pressure Differential Liquid CO2 - Minimum
Not Applicable
Nominal Pipe Size
1 1/4 in
Operating Pressure Differential Hot Water - Minimum
Not Applicable
Operating Pressure Differential Fuel Oil - Minimum
Not Applicable
Mounting Orientation
Vertical
Operating Pressure Differential - Maximum
5 psi
Operating Pressure Differential Air/Inert Gas - Maximum
5 psi
Valve Starting Configuration
Configurable
Operating Pressure Differential - Minimum
0 psi
Inlet Connection Type
NPTF
Valve Positions
2-Position
For Media
Air, Inert Gases, Liquid Propane Gas, Natural Gas, Oxygen
Environmental Rating
Hazardous, Indoor, Outdoor
Operating Pressure Differential Cryogenic Fluid - Maximum
Not Applicable
Operating Pressure Differential Water - Maximum
5 psi
Operating Pressure Differential Cryogenic Fluid - Minimum
Not Applicable
Coefficient of Volume (Cv)
32
Operating Pressure Differential Natural Gas - Maximum
Not Applicable
Fluid Temperature - Maximum
125 Degrees F
Country of Origin (subject to change)
Mexico