Item
Advcntrlunitcl103Ph 01506A 24Vdc
Overload Relay Amp Setting
0.15 to 0.6 A
Features
Protection against overload and short-circuit; Protection against phase failure and phase imbalance; Earth fault protection; Manual reset; Free of Halogen, Mercury u0026 Pvc; Resistance to Electrostatic Discharge, Fast Transients, Radiated Fields, Shock u0026 Vibration
Standards
EN 60947-6-2, IEC 60947-6-2, UL 60947-4-1, with phase barrier, CSA C22.2 No 60947-4-1, with phase barrier
Protective Treatment
TH IEC 60068
Typical Current Consumption
130 mA 24 V DC I maximum while closing with LUB12, 220 mA 24 V DC I maximum while closing with LUB32, 220 mA 24 V DC I maximum while closing with LUB38, 60 mA 24 V DC I rms sealed with LUB12, 80 mA 24 V DC I rms sealed with LUB32, 80 mA 24 V DC I rms sealed with LUB38
Product Specific Application
basic protection and advanced functions, communication
Resistance To Radiated Fields
10 V/m 3 IEC 61000-4-3
Operating Altitude
6561.68 ft (2000 m)
Vibration Resistance
2 gn 5-300 Hz power poles open IEC 60068-2-6, 4 gn 5-300 Hz power poles closed IEC 60068-2-6
Range of Product
TeSys Ultra
Control Circuit Voltage Limits
20...27 V DC 24 V in operation, 14.5 V DC 24 V drop-out
Tripping Threshold
14.2 x Ir +/- 20 %
Thermal Overload Class
class 10 40-60 Hz -25-70°C IEC 60947-6-2, class 10 40-60 Hz -25-70°C UL 508
Heat Dissipation
2-2 W control circuit with LUB12, 3-3 W control circuit with LUB32, 3-3 W control circuit with LUB38
Ambient Air Temperature For Storage
-40-85°C
Motor Power Kw
0.09 kW 400...440 V AC 50/60 Hz
Network Frequency
40...60 Hz
[Uimp] Rated Impulse Withstand Voltage
6 kV IEC 60947-6-2
Device Application
motor control, motor protection
Utilisation Category
AC-41, AC-43, AC-44
Shock Resistance
10 gn power poles open IEC 60068-2-27, 15 gn power poles closed IEC 60068-2-27
[Uc] Control Circuit Voltage
24 V DC
Product or Component Type
advanced control unit
Resistance To Fast Transients
2 kV 3 serial link IEC 61000-4-4, 4 kV 4 all circuits except for serial link IEC 61000-4-4
Load Type
3-phase motor self-cooled
Immunity To Radioelectric Fields
10 V IEC 61000-4-6
Fire Resistance
960°C parts supporting live components IEC 60695-2-12, 650°C IEC 60695-2-12
Resistance To Electrostatic Discharge
8 kV 3 in open air IEC 61000-4-2, 8 kV 4 on contact IEC 61000-4-2
Immunity To Microbreaks
3 ms
Fixing Mode
plug-in (front face)
Operating Time
35 ms opening with LUB12 control circuit, 35 ms opening with LUB32 control circuit, 35 ms opening with LUB38 control circuit, 70 ms closing with LUB12 control circuit, 70 ms closing with LUB32 control circuit, 70 ms closing with LUB38 control circuit
Safe Separation of Circuit
400 V SELV between the control and auxiliary circuits IEC 60947-1, 400 V SELV between the control or auxiliary circuit and the main circuit IEC 60947-1
Product Compatibility
power base LUB12, power base LUB32, power base LUB38, power base LUB120, power base LUB320, power base LUB380, reversing contactor breaker LU2B12BL, reversing contactor breaker LU2B32BL, reversing contactor breaker LU2B38BL
Immunity To Voltage Dips
70 % / 500 ms IEC 61000-4-11
Ambient Air Temperature For Operation
-25-70°C
Function Available
protection against overload and short-circuit, protection against phase failure and phase imbalance, earth fault protection, manual reset
[Ui] Rated Insulation Voltage
690 V IEC 60947-6-2, 600 V UL 60947-4-1, 600 V CSA C22.2 No 60947-4-1
Ip Degree of Protection
IP20 front panel and wired terminals IEC 60947-1, IP20 other faces IEC 60947-1, IP40 front panel outside connection zone IEC 60947-1
[Ue] Rated Operational Voltage
690 V AC
Thermal Protection Adjustment Range
0.15-0.6 A
Rated Insulation Voltage
690 V IEC 60947-6-2; 600 V UL 60947-4-1; 600 V CSA C22.2 No 60947-4-1
Product Or Component Type
Advanced control unit
Main Function Available
Protection against overload and short-circuit; Protection against phase failure and phase imbalance; Earth fault protection; Manual reset
Rated Operational Voltage
690 V AC
Product Certifications
CE; UL; CSA; CCC; EAC; ASEFA; ATEX; Marine
Motor Power KW
0.09 kW 400 to 440 V AC 50/60 Hz
Phase Failure Sensitivity
Yes
IP Degree Of Protection
IP20 front panel and wired terminals IEC 60947-1; IP20 other faces IEC 60947-1; IP40 front panel outside connection zone IEC 60947-1
Rated Impulse Withstand Voltage
6 kV IEC 60947-6-2
Control Circuit Voltage
24 V DC
Safe Separation Of Circuit
400 V SELV between the control and auxiliary circuits IEC 60947-1; 400 V SELV between the control or auxiliary circuit and the main circuit IEC 60947-1
Country of Origin (subject to change)
France