Promotion Restriction
Not eligible for promotion
Output Test Voltage
50 to 5000V DC
Insulation Resistance Range
5 megaohm to 100 gigohm
Live Circuit Detection
Greater Than 30V
Capacitance Range
0.01 to 15 uF
Features
Saves Test Results to the Cloud, Real Time Trending Gives You Easy-to-See Visual Cues, Report Creation Using Fluke Connect Desktop
Data Logging
99 Data Points
Safety Rating
CAT III 1000V, CAT IV 600V
Includes
AC Power Cord, Infrared Adapter with Interface Cable, Soft Carrying Case (Base Models Only), Test Cables with Alligator Clips (Red, Black, Green)
Leakage Current Range
1 mA
Manufacturers Warranty Length
3 yr
Calibration Certificate
None
Green Environmental Attribute
Product is Rechargeable
Communication Protocol
USB
CAT Safety Rating
CAT III 1000V, CAT IV 600V
Parameters Measured
Insulation Resistance
Test Voltage
1,000V DC, 2,500V DC, 250V DC, 5,000V DC, 500V DC
Maximum Capacitance Measured
15 uF
Standards
IEC 61326-1, IEC 61326-2-2 CISPR 11
Backlit Digital Display
No
Minimum Capacitance Measured
0.01 uF
Minimum Insulation Resistance
5 megaohm
Insulation Resistance Resolution
5 megaohm to 100 gigaohm
Testing Functions
Insulation
Maximum Insulation Resistance
100 gigohm
Timed Ramp Voltage Test
Yes
USB Data Download Included
Yes
Live Circuit Voltage
Greater Than30V
Remote Test Probe Included
No
Number of Records Stored
99
Capacitance Auto Discharge
Yes
Battery Chemistry
Lead Acid
Greater Than 30V Warning
Yes
Maximum Operating Temperature
122 Degrees F
Manufacturer Warranty Length
3 yr
Minimum DC Voltage Measured
250 V
Operating Voltage
600V AC/DC
Insulation Limit Alarm
Yes
Maximum DC Voltage Measured
5,000 V
Minimum Operating Temperature
-4 Degrees F
Pass/Fail Selection Limits
Yes
Country of Origin (subject to change)
United States