Item
Emergency Cable Pull Switch
Switch Function
Maintained
AC Contact Rating
3A @ 240V AC
Operating Force
Not Applicable
Switching Ability
Single Cable
DC Contact Rating
0.27A @ 250V DC
For Use With
Preventa XPS Safety Relays
Standards
CSA Certified, UL Listed
Min. Current
Not Applicable
Cable Connection Location
Left
Length (Straight Wireway)
9.0 in
Product Certifications
UL category NISD emergency stop devices || CSA || CCC
Trigger Cable Maximum Length
70 m
Vibration Resistance
10 gn 10-300 Hz)EN/IEC 60068-2-6
Cable Entry Number
3 plain hole Pg 13.5 or ISO M20 cable gland
Tightening Torque
0.8-1.2 N.m
Maximum Resistance Across Terminals
25 MOhm EN/IEC 60255-7 category 3 || 25 MOhm NF C 93-050 method A
Product Or Component Type
latching emergency stop rope pull switch
[Ie] Rated Operational Current
3 A 240 V, AC-15, A300 EN/IEC 60947-5-1 appendix A || 0.27 A 250 V, DC-13, Q300 EN/IEC 60947-5-1 appendix A
Cover Material
stainless steel
Overvoltage Category
class I EN/IEC 61140 || class I NF C 20-030
Terminals Description Iso N°1
(13-14)NO || (21-22)NC
Ambient Air Temperature For Operation
-25-70°C
[Ithe] Conventional Enclosed Thermal Current
10 A
Trigger Cable Anchor Point
LH side
Contacts Type And Composition
1 NC + 1 NO
Ip Degree Of Protection
IP66 IEC 60529
Distance Between Cable Supports
5-5 m
Contact Operation
slow-break
Short-Circuit Protection
10 A cartridge fuse gG EN/IEC 60269
[Uimp] Rated Impulse Withstand Voltage
6 kV EN/IEC 60947-1
Connections - Terminals
screw clamp terminal, 1 x 0.5 to 2 x 1.5 mm?
Shock Resistance
50 gn 11 ms EN/IEC 60068-2-27
Housing Colour
red RAL 3000
[Ui] Rated Insulation Voltage
500 V 3)EN/IEC 60947-1 || 300 VUL 508 || 300 VCSA C22.2 No 14
Safety Level
can reach PL = e with the appropriate monitoring system and correctly wired EN/ISO 13849-1 || can reach category 4 with the appropriate monitoring system and correctly wired EN/ISO 13849-1 || can reach SIL 3 with the appropriate monitoring system and correctly wired EN/IEC 61508
Positive Opening
with EN/IEC 60947-5-1
Ambient Air Temperature For Storage
-40-70°C
Local Signalling
without pilot light
Mechanical Durability
60000 cycles
Country of Origin (subject to change)
Multiple