Promotion Restriction
Not eligible for promotion
Includes
(4) TRM50 Cable Terminators, (4) VPS410-II Probes, AC Power Adapter, Carrying Case, DWA-131 Wi-Fi Dongle, Hand Strap, Hanging Strap, Power Cord, USB Cable
Features
10,000 Points per Trace Waveform Capture (Scope Mode), 4 Independently Floating Isolated Inputs Up to 1000V, 999 Count DMM (2-ch Models: Insulated 5,000 Counts DMM Built-In), Automatic Capture and Replay of 100 Screens, Connect-and-View(TM) Triggering, Frequency Spectrum Analysis Using FFT-Analysis, ScopeRecord(TM) Roll Mode, TrendPlot(TM) Paperless Recorder Mode with Deep Memory, Up to 5 GS/s High-Speed Sampling
Input Sensitivity
With 10:1 Probe, 20 mV to 1000 V/div_x000B; With 100:1 Probe, 200 mV to 10 kV/div _x000B; Direct (1:1), 2 mV to 100 V/div
Real Time Clock
Yes, Provides Date and Time Stamp Information for ScopeRecord, for 100 Screen Replay Sequences and for TrendPlot Recordings
Waveform / Measurement Stored
Two Multiple Input ScopeRecord Waveforms Can Be Saved Internally for Later Recall And Analysis
Safety Rating
CAT III 1000V/CAT IV 600V
Calibration Certificate
Yes
Manufacturers Warranty Length
1 yr (Battery and Accessories), 3 yr (Main Instrument)
Persistence
Off, Short, Medium, Long, Infinite and Envelope Mode
Battery Type
Rechargeable Li-Ion
Max./Min. Sweep Speed
5 nsec/div to 4 sec/div
Max. Record Length
10k/ Channel
AC Voltage Measurement - Minimum
500 mV AC
CAT Safety Rating
CAT III 1000V, CAT IV 600V
Memory Depth
30,000 Data Points Per Channel
Digital Display Screen Type
LCD
Standards
EN 61010-1, IEC 61010-2-030: CAT IV 600V/CAT III 1000V
Input Sensitivity - Maximum
100 V/div
Display Screen Width
3.5 in
Capacitance Measurement - Maximum
Not Applicable
Calibration Certificate Type
Not Certified
DC Voltage Measurement - Maximum
1,100 V DC
AC Voltage Measurement Resolution
100 mV
AC Current Measurement - Maximum
Not Applicable
Time Base - Minimum
5 nsec/div
DC Voltage Measurement - Minimum
500 mV DC
DC Current Measurement - Maximum
Not Applicable
AC Voltage Measurement - Maximum
1,100 V AC
Basic DC Voltage Accuracy
+/-(0.50% +6 Counts)
Includes Batteries
Batteries Included
Display Screen Length
5.2 in
DC Current Measurement - Minimum
Not Applicable
Battery Chemistry
Lithium Ion
Basic AC Voltage Accuracy
+/-(1% +10 Counts)
Input Sensitivity - Minimum
100 V/div
AC Magnitude Calculation
True RMS
Time Base - Maximum
4 sec/div
Capacitance Measurement - Minimum
Not Applicable
AC Current Measurement - Minimum
Not Applicable
Channel Source Isolation
Fully Isolated
Country of Origin (subject to change)
Romania