Promotion Restriction
Not eligible for promotion
Accuracy
+/-0.2 Degrees C Full Range
Thermocouple Type
C, E, J, K, L, M, N, R, S, T, U
Loop Supply Voltage
24V DC
RTD Type
4 Wire, 3 Wire, 2 Wire
RTD Temperature Range
-139 Degrees to 284 Degrees F (-95 Degrees to 140 Degrees C)
Thermocouple Temperature Range
-139 Degrees to 284 Degrees F (-95 Degrees to 140 Degrees C)
Calibration Certificate
yes
Includes
6 ft Main Power Cord, 9930 Interface-It Calibration Software and Users Guide, Getting Started Manual, Insert Removal Tool, Product CD, Report of Calibration and Calibration Label, USB Cable, Well Insulator Cap
Agency Compliance
EU Directives, CSA, Australian EMC Requirements
Interface
RS-232, USB Cable
Max. Loop Current
4 to 20mA
Standards
IEC 61010-1, Installation Category II, Pollution degree 2, IEC 61326-1: Basic
RTD Temperature Range F
-139 Degrees to 284 Degrees F
Reference Junction Temperature Characteristics
+/- 0.35 Degrees C Accuracy at Ambient Temperature of 13 Degrees to 33 Degrees C
Display Temperature Accuracy
+/-0.2 Degrees C
Stability
+/-0.015 Degrees C
Sensor Type
RTD, Thermocouple
Typical Uniformity
+/-0.05 Degrees C
Power Source Details
100 to 115V, 200 to 230V
Well Size
1 3/16 in Dia x 6 5/16 D Well
Typical Cooling Time
80 min (23 Degrees to -90 Degrees C), 90 min (23 Degrees to -95 Degrees C), 60 min (140 Degrees to 23 Degrees C)
Thermocouple Temperature Range F
-139 Degrees to 284 Degrees F
Display Resolution
0.01 Degrees
With Process Connections
Yes
Application
Blood Banks, Cold Rooms, Freeze Dryers, Laboratory Refrigerators, Medical Freezers, Sterilizers (Autoclaves)
Temperature Range
-139 Degrees to 284 Degrees F/-95 Degrees to 140 Degrees C
For RTD Type
2-Wire, 3-Wire, 4-Wire, Ni-120, PT-100 (385), PT-100 (3926), PT-100 (JIS)
For Thermocouple Type
Type C, Type E, Type J, Type K, Type L, Type M, Type N, Type R, Type S, Type T, Type U
Thermocouple Temperature Range C
-95 Degrees to 140 Degrees C
RTD Temperature Range C
-95 Degrees to 140 Degrees C
Thermocouple Temperature Accuracy Characteristics
Type C: +/-1.00 Degrees C at 140 Degrees C, Type E: +/-0.60 Degrees C at 140 Degrees C, Type J: +/-0.70 Degrees C at 140 Degrees C, Type K: +/-0.75 Degrees C at 140 Degrees C, Type L: +/-0.65 Degrees C at 140 Degrees C, Type M: +/-0.65 Degrees C at 140 Degrees C, Type N: +/-0.75 Degrees C at 140 Degrees C, Type R: +/-1.60 Degrees C at 140 Degrees C, Type S: +/-1.60 Degrees C at 140 Degrees C, Type T: +/-0.60 Degrees C at 140 Degrees C, Type U: +/-0.70 Degrees C at 140 Degrees C
Calibrator Accuracy
+/-0.2 Degrees C
Thermocouple mV Characteristics
0.025% + 0.01 mV at -10 to 75 mV
Reference Input Temperature Characteristics
+/-0.010 Degrees C at -95 Degrees C, +/-0.013 Degrees C at -25 Degrees C, +/-0.015 Degrees C at 0 Degrees C, +/-0.020 Degrees C at 50 Degrees C, +/-0.025 Degrees C at 140 Degrees C
Overall Dimensions
18 13/16 in H x 8 in W x 14 29/32 in D
Typical Heating Time
40 min (-95 Degrees to 140 Degrees C)
Probe Connection Types
(1) 4-Terminal RTD Input, (1) Miniature connectors (ASTM E1684)
Resistance Sensing Current Characteristics
0.02% at 0.002 mA; Cal 4-22 mA, Spec 4-24 mA
Current mA Characteristics
0.02% + 0.002 mA Accuracy/4 to 22 mA, 4 to 24 mA Range
Reference Input Resistance Characteristics
+/--0.0025 ohm Accuracy (0 to 42 ohm), +/-60 ppm of Reading Accuracy (42 to 400 ohm)
Calibrator Type
Field Metrology Well
For Stem Diameter
(2) 3 mm, (2) 4 mm, (2), 6 mm
Brand and Series
Fluke 9190A
Number of Set Points
Variable
Set Point Style
Adjustable
Single Well/Dual Well
Single Well
4-Wire Device Resistance Characteristics
Range: 0 to 400 ohms/Accuracy: +/-0.0025 ohms (0 to 42 ohms), +/-60 ppm of Reading (42 to 400 ohms)
Temperature Accuracy
+/-0.2 Degrees C
Country of Origin (subject to change)
United States