Promotion Restriction
Not eligible for promotion
Loop Supply Voltage
24V DC
Accuracy
+/-0.2 Degrees C Full Range
Thermocouple Type
C, E, J, K, L, M, N, R, S, T, U
RTD Type
4 Wire, 3 Wire, 2 Wire
RTD Temperature Range
-139 Degrees to 284 Degrees F (-95 Degrees to 140 Degrees C)
Thermocouple Temperature Range
-139 Degrees to 284 Degrees F (-95 Degrees to 140 Degrees C)
Calibration Certificate
yes
Includes
6 ft Main Power Cord, 9190 Insert C, 9930 Interface-It Calibration Software and Users Guide, Getting Started Manual, Insert Removal Tool, Product CD, Report of Calibration and Calibration Label, USB Cable, Well Insulator Cap
Agency Compliance
EU Directives, CSA, Australian EMC Requirements
Max. Loop Current
4 to 20mA
Interface
RS-232, USB Cable
Standards
IEC 61010-1, Installation Category II, Pollution degree 2, IEC 61326-1: Basic
RTD Temperature Range F
-139 Degrees to 284 Degrees F
Calibrator Type
Field Metrology Well
Brand and Series
Fluke 9190A
Stability
+/-0.015 Degrees C
Current mA Characteristics
0.02% + 0.002 mA Accuracy/4 to 22 mA, 4 to 24 mA Range
Overall Dimensions
18 13/16 in H x 8 in W x 14 29/32 in D
Resistance Sensing Current Characteristics
0.02% at 0.002 mA; Cal 4-22 mA, Spec 4-24 mA
Probe Connection Types
(1) 4-Terminal RTD Input, (1) Miniature Connectors (ASTM E1684)
Power Source Details
100 to 115V, 200 to 230V
With Process Connections
Yes
Well Size
1 3/16 in Dia x 6 5/16 D Well
Typical Cooling Time
80 min (23 Degrees to -90 Degrees C), 90 min (23 Degrees to -95 Degrees C), 60 min (140 Degrees to 23 Degrees C)
Thermocouple Temperature Accuracy Characteristics
Type C: +/-1.00 Degrees C at 140 Degrees C, Type E: +/-0.60 Degrees C at 140 Degrees C, Type J: +/-0.70 Degrees C at 140 Degrees C, Type K: +/-0.75 Degrees C at 140 Degrees C, Type L: +/-0.65 Degrees C at 140 Degrees C, Type M: +/-0.65 Degrees C at 140 Degrees C, Type N: +/-0.75 Degrees C at 140 Degrees C, Type R: +/-1.60 Degrees C at 140 Degrees C, Type S: +/-1.60 Degrees C at 140 Degrees C, Type T: +/-0.60 Degrees C at 140 Degrees C, Type U: +/-0.70 Degrees C at 140 Degrees C
RTD Temperature Range C
-95 Degrees to 140 Degrees C
Thermocouple mV Characteristics
0.025% + 0.01 mV at -10 to 75 mV
Reference Input Temperature Characteristics
+/-0.010 Degrees C at -95 Degrees C, +/-0.013 Degrees C at -25 Degrees C, +/-0.015 Degrees C at 0 Degrees C, +/-0.020 Degrees C at 50 Degrees C, +/-0.025 Degrees C at 140 Degrees C
Thermocouple Temperature Range F
-139 Degrees to 284 Degrees F
Calibrator Accuracy
+/-0.2 Degrees C
For Thermocouple Type
Type C, Type E, Type J, Type K, Type L, Type M, Type N, Type R, Type S, Type T, Type U
Typical Uniformity
+/-0.05 Degrees C
Temperature Range
-139 Degrees to 284 Degrees F/-95 Degrees to 140 Degrees C
For RTD Type
2-Wire, 3-Wire, 4-Wire, Ni-120, PT-100 (385), PT-100 (3926), PT-100 (JIS)
Thermocouple Temperature Range C
-95 Degrees to 140 Degrees C
Typical Heating Time
40 min (-95 Degrees to 140 Degrees C)
Application
Blood Banks, Cold Rooms, Freeze Dryers, Laboratory Refrigerators, Medical Freezers, Sterilizers (Autoclaves)
Display Resolution
0.01 Degrees
For Stem Diameter
(6) 1/4 in
Sensor Type
RTD, Thermocouple
Display Temperature Accuracy
+/-0.2 Degrees C
Reference Junction Temperature Characteristics
+/- 0.35 Degrees C Accuracy at Ambient Temperature of 13 Degrees to 33 Degrees C
Reference Input Resistance Characteristics
+/--0.0025 ohm Accuracy (0 to 42 ohm), +/-60 ppm of Reading Accuracy (42 to 400 ohm)
4-Wire Device Resistance Characteristics
Range: 0 to 400 ohms/Accuracy: +/-0.0025 ohms (0 to 42 ohms), +/-60 ppm of Reading (42 to 400 ohms)
Number of Set Points
Variable
Single Well/Dual Well
Single Well
Set Point Style
Adjustable
Temperature Accuracy
+/-0.2 Degrees C
Country of Origin (subject to change)
United States