Water Heater Design
Point-of-Use
Voltage - Water Heaters
240V/208V
Watts - Water Heaters
9,600 W
Temp. Range - Water Heaters
82 Degrees to 130 Degrees F
Min. Flow Activation
0.8 gpm
Water Heater Application
General Purpose
Commercial / Residential
Commercial
Item
Electric Tankless Water Heater
Features
Cold Water Only Line Needed to Be Run to Lavatory, Compatible with Sensor Actuated or Metered Faucets, Prevents Dry Firing, Flow Switch for Virtually Silent Operation, High Limit Switch with Manual Reset
Temp. Rise @ 6.0 GPM
8 Degrees F
Standards
499 and Conform to CAN/CSA E335-1/3E and E335-2-35, ANSI ANSI/UL Standard
Temp. Rise @ 1.5 GPM
44 Degrees F
Temp. Rise @ 4.0 GPM
16 Degrees F
Item - Water Heaters
Electric Tankless Water Heaters
Temp. Rise @ 2.5 GPM - Water Heaters
26 Degrees F
Water Connection
1/2 in NPT
Cord Conductor Gauge
8/2 AWG Wire
Minimum Water Pressure
30 psi
Maximum Delivered Temperature
130 Degrees F
Element Material
Copper-Clad
Maximum Flow Rate
Not Applicable
Application
Commercial Condominiums, Gas Stations, Hotels, Malls, Manufacturing Facilities, Motels, Office Buildings, Restaurants, Schools, Stores, Warehouses
Maximum Water Pressure
150 psi
Minimum Delivered Temperature
82 Degrees F
Temperature Rise @ Flow
33 to 25 Degrees F @ 2 gpm, 44 to 33 Degrees F @ 1.50 gpm, 65 to 49 Degrees F @ 1 gpm
Operating Voltage
240/208V AC
Manufacturer Warranty Length
3 yr Parts Warranty, 7 yr Leakage
Hot Outlet Connection Gender
Female
Mounting Type
Wall Mounting
Minimum Flow Activation
0.8 gpm
Country of Origin (subject to change)
Germany