Item
Electromechanical Timer
Number of Trippers Included
2
Nominal Max. Time Setting
24 hr
Description/Special Features
3R Enclosures in Steel or Noncorrosive Plastic, Furnished with a Maximum of 12 Trippers, Has Adjustable Time Setting, Manual On/Off Override does not Alter Program, Snap-out Timing Mechanism, Up to 12 On/Off Settings Per Day
Time Setting Range
1 hr. to 23 hr.
Operating Temperature Min
-40°C
Application Compatibilities
LED; HID
Product Height
10 in; 254 mm
Product Width
6 1/2 in; 165.1 mm
Knockout Dimensions Back
(1) combination 1/2\
Tungsten Load Ratings
40 A, 120 VAC, 60 Hz; 40 A, 208 VAC, 60 Hz; 40 A, 240 VAC, 60 Hz
Packaging Applications
Indoor/Outdoor Lighting; Signs; Filters; Electric Fences; Fans; Conveyors; Pool Heaters; Blowers; Pumps
Resistive Load Ratings
40 A, 240 VAC, 60 Hz; 40 A, 208 VAC, 60 Hz; 40 A, 120 VAC, 60 Hz
Knockout Dimensions Bottom
(2) combination 1/2\
Pilot Duty Load Ratings Ranges
1000 VA, 120-240 VAC, 60 Hz
Solutions
Machinery \u0026 Pumps; Panel Integrators
Motor Load Ratings
2 HP, 24 FLA @ 120 VAC, 60 Hz; 5 HP, 28 FLA @ 240 VAC, 60 Hz
UL Cerfication File Number
UL917
Tungsten Load Ratings Ranges
40 A, 120-240 VAC, 60 Hz
Operating Temperature Max
130°C
Market
Commercial; Industrial
Power Consumption Max W
3 W
Inductive Load Ratings Ranges
40 A, 120-240 VAC, 60 Hz
Skipper Wheel Operation Mode
Not Included
Electronic Ballast Load Ratings Ranges
16 A, 120 VAC
Product Depth
4 in; 101.6 mm
Applications
Timing/Scheduling ON/OFF; Indoor Lighting Control; Outdoor Lighting Control
Electronic Ballast Load Ratings
16 A, 120 VAC
Minimum On Off Time
1 hour
Has Manual Override CVL
Yes
Pilot Duty Load Ratings
1000 VA, 120-240 VAC, 60 Hz
Resistive Load Ratings Ranges
40 A, 120-240 VAC, 60 Hz
Inductive Load Ratings
40 A, 240 VAC, 60 Hz; 40 A, 208 VAC, 60 Hz; 40 A, 120 VAC, 60 Hz
Input Voltage Ranges
120 VAC, 60 Hz
Maximum On Off Operations
12
Maximum ON/OFF Operations
12
Minimum ON/OFF Times
1 hour
Operating Temperature Min (°F)
-40
Maximum Power Consumption (W)
3 W
Pilot Duty (NO)
1000 VA, 120-240 VAC, 60 Hz
Tungsten (NO)
40 A, 120 VAC, 60 Hz, 40 A, 208 VAC, 60 Hz, 40 A, 240 VAC, 60 Hz
Resistive
40 A, 120 VAC, 60 Hz, 40 A, 208 VAC, 60 Hz, 40 A, 240 VAC, 60 Hz
Skipper Wheel
Not Included
Inductive
40 A, 120 VAC, 60 Hz, 40 A, 208 VAC, 60 Hz, 40 A, 240 VAC, 60 Hz
Input Voltage Range(s)
120 VAC, 60 Hz
Motor Load Ratings Ranges
2 HP, 24 FLA @ 120 VAC, 60 Hz; 5 HP, 28 FLA @ 240 VAC, 60 Hz
Operating Temperature Max (°F)
130
Electronic Ballast
16 A, 120 VAC
Tungsten Range(s)
40 A, 120-240 VAC, 60 Hz
Operating Temperature - Maximum
130 Degrees F
Time Setting - Minimum
1 hr
Horsepower @ 240V - Maximum
5 hp
On/Off Cycles - Maximum
12
Current Rating - Maximum
40 A
Compatible Lighting
HID, LED
Time Setting - Maximum
24 hr
Indoor/Outdoor Usage
Indoor, Outdoor
Horsepower @ 120V - Maximum
2 hp
Operating Temperature - Minimum
-40 Degrees F
Number of Trippers - Maximum
2
Country of Origin (subject to change)
Mexico