Construction Material
Aluminized Steel
Remarks
View Catalog Page for Selection Criteria
Vent Pipe Dia. (In.)
8 to 12\
For Use With Mfr. Model Number
PS1505
Application
Boilers, Furnaces, Water Heaters
Overload Protection
Thermal
CFM @ 1.000-In. SP
Not Applicable
Heater Btu Input @ 530 (F)
1,100,000 1,100,000 840,000 400,000
CFM @ 390 Deg. (F)
603653615357
Duct Temp. Deg. (F)
Not Applicable
CFM @ 1.40-In. SP
Not Applicable
SP @ 270 Deg. (F)
0.1250.1350.1400.128
SP @ 390 Deg. (F)
0.1430.1500.1450.115
CFM @ 0.700-In. SP
Not Applicable
SP @ 530 Deg. (F)
0.1470.1480.1360.100
CFM @ 530 Deg. (F)
566566440211
Heater Btu Input @ 270 (F)
900,000 1,110,000 1,250,000 1,030,000
CFM @ 270 Deg. (F)
590765850710
Heater Btu Input @ 390 (F)
1,200,000 1,330,000 1,260,000 710,000
Maximum Vent Pipe Diameter
12 in
Minimum Heat Input
400,000 Btu (Oil/Barometric), 710,000 Btu (Gas/Barometric), 900,000 Btu (Gas/Draft Hood)
Minimum Vent Pipe Diameter
8 in
Cutout Size
4 in x 12 3/4 in
Maximum Heater BTU Input for Gas Appliance
1,330,000 BtuH
Maximum Heater BTU Input for Oil Appliance
1,100,000 BtuH
Airflow at Temperature
566 cfm @ 530 Degrees F, 566 cfm @ 530 Degrees F, 440 cfm @ 530 Degrees F, 211 cfm @ 530 Degrees F, 590 cfm @ 270 Degrees F, 765 cfm @ 270 Degrees F, 850 cfm @ 270 Degrees F, 710 cfm @ 270 Degrees F, 603 cfm @ 390 Degrees F, 653 cfm @ 390 Degrees F, 615 cfm @ 390 Degrees F, 357 cfm @ 390 Degrees F
Maximum Heat Input
1,100,000 Btu (Oil/Barometric), 1,250,000 Btu (Gas/Draft Hood), 1,330,000 Btu (Gas/Barometric)
For Appliance Type
Boilers, Furnaces, Non-Condensing Chimney Vented Gas and Oil Fueled Heating Equipment, Ovens, Water Heaters
Maximum Static Pressure
1/8 in wc
For Fuel Type
Natural Gas, Oil
Blower Type
Induced Draft Blower
Country of Origin (subject to change)
United States