Item
Low Voltage Thermostat
Control Range
50 Degrees to 90 Degrees F
System Switching
Auto-Heat-Cool-Off-Aux-Setback
Dual Transformer Compatible
Yes
Power Method
Hardwired/Battery/Power Stealing
Programs per Week
7, 5-2, 5-1-1
Dehumidification Control
Yes
Agency Compliance
ASHRAE 90.1-9, California Title 24
Terminal Designations
C, W1(B/O), W2(AUX), G, A, E, Y1, Y2, RH, RC, SC, S1, S2, S3
Temporary Temperature Hold
Yes
Temp. Settings per Day
0, 1, 2, 4
Remote Sensing Capability
Yes
Features
A Secure Digital (SD) Card Capability for Download/Upload Configuration and Program Settings
For Use With
SB200-001 Occupancy Sensor, SP155-017 INDOOR REMOTE SENSOR, 70327 OUTDOOR REMOTE SENSOR, 70481 SD Card Performance PRO
Humidification Control
Yes
Temporary Program Override
Yes
Green Environmental Attribute
Product Contributes To Reducing Energy Consumption
Footnotes
1, 2, 3, 5, 6, 7, 8
Standards
ASHRAE 90.1-9, California Title 24
Occupancy Sensor
Includes Occupancy Sensor
Stages
3H/2C Conventional, 4H/2C Heat Pump
Type
Digital Programmable Multi Stage H/C or HP
Operating Temperature Range
0 Degrees to 120 Degrees F
Compatible System Type
Electric Forced Air Furnaces, Gas Forced Air Furnaces, Heat Pump with Aux, Heat Pump without Aux
Thermostat Type
Low Voltage
Contact Rating
20 to 30V AC
Changeover Type
Automatic and Manual
Smart Connectivity
No Connectivity
Maximum Operating Humidity
99 %
Temperature settings per day
0, 1, 2, 4
Maximum Operating Temperature
120 Degrees F
Programming Capability
5-1-1, 5-2, 7 Day
Maximum Control Temperature
90 Degrees F
Mounting Direction/Shape
Horizontal
Number of Heating Stages - Heat Pump System
4
Battery Type
(2) AA Batteries
Temperature Control Range
50 Degrees to 90 Degrees F
Temperature Scale
Fahrenheit/Celsius
Electrical Connection Type
Hardwired
Operating Humidity Range
25% to 99% RH
System/Fan Settings
Auto-Cool-Emergency Heat-Heat-Off/Auto-On
Number of Cooling Stages - Conventional System
2
Mounting Direction
Horizontal
Temperature Differential
1 Degrees F
Minimum Control Temperature
50 Degrees F
Application/Stages
Heat and Cool; 3H/2C Conventional, 4H/2C Heat Pump
Number of Heating Stages - Conventional System
3
Filter Change Reminder
Yes
External Power Source
Furnace
System Settings
Auto-Cool-Emergency Heat-Heat-Off
Number of Cooling Stages - Heat Pump System
2
Occupancy Sensor Compatibility
2NCC2, 2NCC8
Minimum Operating Humidity
25 %
Minimum Operating Temperature
0 Degrees F
Country of Origin (subject to change)
China