Item
Molded Case Circuit Breaker
Max. AIR Rating
25kA at 240V AC
Terminal Connection
Line/Load Lug
Circuit Breaker Actuator
Toggle
Circuit Breaker Mounting Style
Free Standing
Circuit Breaker Type
Standard
Standards
BS, CCC, CE Marked, CEI, CSA Certified, Federal Specification W-C-375B/GEN, HACR, HID, IEC, NEMA, NMX, NOM, SWD, UL Listed, UNE, UTE, VDE
Trip Type
Thermal Magnetic
Instantaneous Trip
Adjustable
Phase Connection
Not Applicable
High Amp Trip Setting
1,750 A
Low Amp Trip Setting
875 A
Interrupt Rating
25 kA at 220/240V AC, 18 kA at 380/440/415/480V AC, 14 kA at 500/525/600V AC, 20 kA at 250/500V DC
Features
Mercury Free, PVC Free
Application
HACR rated Applications, Distribution
Tightening Torque
221.27 lbf.in (25 N.m) 0.04 to 0.15 in? (25 to 95 mm?) (AWG 4 to AWG 4/0)
Device Application
Distribution
Trip Unit Technology
Thermal-magnetic
Operating Altitude
Less than 6561.68 ft (2000 m) without derating, 5000 m with derating
Rated Operational Voltage
600 V AC 50/60 Hz IEC 60947-3
Circuit Breaker Application
HACR rated
Rated Impulse Withstand Voltage
8 kV IEC 60947-2
Utilisation Category
Category A
Network Frequency
50/60 Hz
Number Of Slots
2 auxiliary switch OF plug-in), 1 alarm switch SD plug-in), 1 overcurrent trip switch SDE plug-in), 1 voltage release MN or MX plug-in)
IP Degree Of Protection
Front cover IP40
Power Wire Stripping Length
0.98 in (25 mm)
Rated Service Breaking Capacity
25 kA 220/240 V AC 50/60 Hz IEC 60947-2, 18 kA 380/440/415 V AC 50/60 Hz IEC 60947-2, 14 kA 500/525 V AC 50/60 Hz IEC 60947-2, 20 kA 250 V DC IEC 60947-2, 20 kA 500 V DC IEC 60947-2
Rated Insulation Voltage
750 V IEC 60947-2
Protection Type
Overload protection, Short-circuit protection
Breaking Capacity
25 kA 240 V AC 50/60 Hz UL 489, 18 kA 480 V AC 50/60 Hz, 14 kA 600 V AC 50/60 Hz, 20 kA 250 V DC
Ambient Air Temperature For Storage
-58 to 185°F (-50 to 85°C)
Suitability For Isolation
Yes IEC 60947-2
AWG Gauge
AWG 4 to AWG 4/0 aluminium/copper terminal
Magnetic Tripping Current
1750 A
Product Certifications
UL, CSA, NOM
Local Signalling
Switched off (OFF) 1 trip indicator green)
Communication Interface
Modbus, Ethernet
Pollution Degree
3 IEC 60947-1
Mounting Mode
Unit mount lug)
Continuous Current Rating
0.8
Electrical Connection
Lugs, line, Lugs, load
Ambient Air Temperature For Operation
28 to 158°F (-2 to 70°C)
Long Time Pick-Up Adjustment Range
0.25 to 1 x In
Terminal Identifier
AL175JD
Product Or Component Type
Circuit breaker
Country of Origin (subject to change)
Multiple