Item
Programmable Thermostat
Control Range
Cool 50 Degrees to 99 Degrees F, Heat 40 Degrees to 90 Degrees F
System Switching
Auto-Heat-Cool-Off-Emergency
Dual Transformer Compatible
Yes
Power Method
Hardwired/Battery
Programs per Week
7 or Nonprogrammable
Includes
Mfr. No. TH8321R1001 and (2) AA Thermostat Batteries
Humidification Control
Yes
Temporary Program Override
Yes
Dehumidification Control
Yes
Terminal Designations
R, RC, C, W-O/B, W2-AUX/E, Y, Y2, G, A-L/A, K, U1 U1, S1 S1
Features
Smart Schedule, Patented Interview Based Programming and Installer Setup, RedLINK(TM) Wireless Communication, Meets Commercial Code and is Title 24 Compliant, Alerts and User Interactions Log, Customizable Service Reminders, MicroSD Port, Dual Powered - Battery or Hardwired (C Wire), Precise temperature control ( +/-1 Degrees F), Multiple Staging Options
Temporary Temperature Hold
Yes
Remote Sensing Capability
Yes
Fan Switching
Auto-On-Circulate-Follow Schedule
Green Certification or Other Recognition
ENERGY STAR
Stages
2H/2C Conventional, 3H/2C Heat Pump
Occupancy Sensor
Compatible with Occupancy Sensor
Number of Heating Stages - Heat Pump System
3
Application/Stages
Heat and Cool; 2H/2C Conventional, 3H/2C Heat Pump
Wireless System Compatibility
RedLink
Number of Cooling Stages - Heat Pump System
2
System/Fan Settings
Auto-Cool-Emergency Heat-Heat-Off/Auto-Circulate-Follow Schedule-On
Thermostat Type
Low Voltage
Maximum Control Temperature
99 Degrees F
Temperature Control Range
40 Degrees to 99 Degrees F
Minimum Operating Humidity
5 %
Temperature Scale
Fahrenheit/Celsius
Number of Heating Stages - Conventional System
2
Maximum Operating Humidity
90 %
Differential Type
Adjustable
Mounting Direction/Shape
Horizontal
Minimum Operating Temperature
32 Degrees F
Maximum Operating Temperature
120 Degrees F
Operating Humidity Range
5% to 90% RH
Mounting Direction
Horizontal
Operating Temperature Range
32 Degrees to 120 Degrees F
Temperature settings per day
4
Compatible System Type
Electric Forced Air Furnaces, Gas Forced Air Furnaces, Heat Pump with Aux, Heat Pump without Aux, Hydronic Systems, Millivolt
Number of Cooling Stages - Conventional System
2
Temperature Sensitivity
+/-1.5 Degrees F
Minimum Control Temperature
40 Degrees F
Filter Change Reminder
Yes
Programming Capability
7 Day
System Settings
Auto-Cool-Emergency Heat-Heat-Off
Electrical Connection Type
Hardwired
Temperature Differential
1 Degrees F
Fan Settings
Auto-Circulate-On
Country of Origin (subject to change)
Mexico