Item
Inductive Cylindrical Proximity Sensor
Proximity Sensor Style
Cylindrical Proximity Sensor
Proximity Sensing Method
Inductive
Proximity Sensor Power Requirement
10 to 30V DC
Proximity Sensor Output Circuit Type
3 Wire PNP
Proximity Sensor Diameter
30 mm
Max. Detecting Distance
22 mm
Proximity Sensor Electrical Connection
4 Pin M12 Connector
Basic Proximity Sensor Case Material
Metal
Shielded / Unshielded
Unshielded
Proximity Sensor Operating Frequency
100 Hz
Case Material
Brass White Bronze Coated
Standards
EN 61000-4-2 ESD, EN 55011, EN 60068-2-14 Na, EN 60068-2-27, EN 60068-2-52 Kb, EN 60068-2-6 FC, EN 61000-4-3 HF Radiated, EN 61000-4-4 Burst, EN 61000-4-6 HF Conducted, UL E174191, UL A001
Operating Temp. Range
-40 Degrees to 185 Degrees F
IP Rating
IP65, IP66, IP67, IP68, IP69K
Description/Special Features
Overload And Short Protection
Length (Straight Wireway)
60 mm
Continuous shock resistance
EN 60068-2-27 40 g 6 ms; 4000 shocks each in every direction of the 3 coordinate axes
Operating voltage [V]
10...30 DC
Application
Suitable for industrial, mobile, cooling and lubricating applications; Industrial applications / factory automation
Correction factor
steel: 1 / stainless steel: 0.7 / brass: 0.5 / aluminium: 0.4 / copper: 0.3
Protection
IP 65; IP 66; IP 67; IP 68; IP 69K
Switch point drift [% of Sr]
-10...10
Reverse polarity protection
yes
Short-circuit protection
yes
Increased sensing range
yes
Hysteresis [% of Sr]
3...15
Operating distance [mm]
0...17.82
Connection
Connector: 1 x M12; coding: A; Contacts: gold-plated
Max. voltage drop switching output DC [V]
2.5
Switching frequency DC [Hz]
100
Dimensions [mm]
M30 x 1.5 / L = 60
Display
switching status 4 x LED, yellow
Output function
normally open
Vibration resistance
EN 60068-2-6 Fc 20 g (10...3000 Hz) / 50 sweep cycles, 1 octave per minute, in 3 axes
UL approval
Ta -25...70°C Enclosure type Type 1 power supply Limited Voltage/Current UL Approval no. A001 File number UL E174191
EMC
EN 61000-4-2 ESD 4 kV CD / 8 kV AD EN 61000-4-3 HF radiated 10 V/m EN 61000-4-4 Burst 2 kV EN 61000-4-6 HF conducted 10 V EN 55011 class B
Special feature
Gold-plated contacts; Increased sensing range
Ambient temperature [°C]
-40...85
Salt spray test
EN 60068-2-52 Kb severity level 5 (4 test cycles)
Mounting
non-flush mountable
Real sensing range Sr [mm]
22± 10 %
Materials
brass white bronze coated; sensing face: PBT orange; LED window: PEI; lock nuts: brass white bronze coated
Permanent current rating of switching output DC [mA]
100
Thread designation
M30 x 1.5
Fast temperature change
EN 60068-2-14 Na TA = -40°C; TB = 85°C; t1 = 30 min; t2 = < 10 s; 50 cycles
Shock resistance
EN 60068-2-27 Ea 100 g 11 ms half-sine; 3 shocks each in every direction of the 3 coordinate axes
Embedded software included
yes
Items supplied
lock nuts: 2
Current consumption [mA]
< 10
Ambient temperature [°C]
-40...85
Overall Depth
Not Applicable
Operating Temperature - Minimum
-40 Degrees F
Output Circuit Voltage - Maximum
2.5 V DC
Sensing Face Shielding
Unshielded
AC Voltage Rating
Not Rated
Output Circuit Current - Maximum
100 mA
Includes Indicator Lights
Indicator Lights Included
Ring Inside Diameter
Not Applicable
Output Circuit Number of Wires
3
Sensing Distance - Maximum
22 mm
Operating Temperature - Maximum
185 Degrees F
Overall Width
Not Applicable
Resolution of Steel Ball Diameter
Not Applicable
Electrical Installation Type
Direct Connector
DC Voltage Rating
10-30V DC
Switching Frequency
100 Hz
Output Circuit Contact Form
NO
Country of Origin (subject to change)
Germany