Item
Capacitive Cylindrical Proximity Sensor
Proximity Sensor Style
Cylindrical Proximity Sensor
Proximity Sensing Method
Capacitive
Proximity Sensor Power Requirement
20 to 250V AC/DC
Proximity Sensor Output Circuit Type
2 Wire
Proximity Sensor Diameter
18 mm
Max. Detecting Distance
12 mm
Proximity Sensor Electrical Connection
2 Pin 1/2 in UNF Connector
Basic Proximity Sensor Case Material
Plastic
Shielded / Unshielded
Unshielded
Proximity Sensor Operating Frequency
10 Hz
Max. Current Load
150/100mA
Description/Special Features
Yellow LED Output Indication
Operating Temp. Range
-13 Degrees to 176 Degrees F
Electrical Connection
1/2 in Connector
Length (Straight Wireway)
87 mm
Switching frequency AC [Hz]
10
Operating voltage [V]
30...250 AC / 20...250 DC
Real sensing range Sr [mm]
12± 10 %
Switching frequency DC [Hz]
10
Permanent current rating of switching output DC [mA]
100; (150 (...40°C))
Switch point drift [% of Sr]
-20...20
Permanent current rating of switching output AC [mA]
100; (150 (...40°C))
Factory setting sensing range [mm]
12
Sensing range adjustable
yes
Display
switching status 1 x LED ring, yellow plug lights translucently
Electrical connection
Connector: 1 x 1/2\
Max. leakage current [mA]
2.5 (250 V AC) / 1.7 (110 V AC) / 1.5 (24 V DC)
Hysteresis [% of Sr]
1...15
Output function
normally open / normally closed; (selectable)
Required protection
miniature fuse to IEC60127-2 sheet 1; ≤2 A; fast acting
Reverse polarity protection
yes
Dimensions [mm]
M18 x 1 / L = 87
Thread designation
M18 x 1
Correction factor
glass: 0.4 / water: 1 / ceramics: 0.2 / PVC: 0.1
Items supplied
lock nuts: 2
Recommended media
media with a dielectric constant \u003c 20; oils
Media
dry bulk material; liquids
Sensing range [mm]
4...24; (programming buttons)
Max. voltage drop switching output AC [V]
10
Installation
detection through non-metallic container wall or on bypass pipes
Materials
housing: PBT; pushbuttons: TPE-U; LED window: PC
Max. voltage drop switching output DC [V]
8
Ambient temperature [°C]
-25...80
Mounting
non-flush mountable
Short-time current rating of switching output [mA]
1000; (20 ms / 0,5 Hz)
Ambient temperature [°C]
-25...80
Output Circuit Voltage - Maximum
8 V DC
Electrical Installation Type
Direct Connector
AC Voltage Rating
30-250V AC
Includes Indicator Lights
Indicator Lights Included
DC Voltage Rating
20-250V DC
Ring Inside Diameter
Not Applicable
Output Circuit Current - Maximum
100 mA
Sensing Distance - Minimum
4 mm
Output Circuit Contact Form
NO or NC
Operating Temperature - Minimum
-13 Degrees F
Overall Width
Not Applicable
Sensing Face Shielding
Unshielded
Overall Depth
Not Applicable
Output Circuit Number of Wires
2
Output Circuit Type
AC/DC-Type
Operating Temperature - Maximum
176 Degrees F
Switching Frequency
10 Hz (AC), 10 Hz (DC)
Sensing Distance - Maximum
24 mm
Resolution of Steel Ball Diameter
Not Applicable
Country of Origin (subject to change)
Germany