Compatible Material
Concrete
ICC Approved for Cracked Concrete
Yes
Minimum Installation Depth
60 mm
Maximum Material Thickness
5 mm
Ultimate Shear Strength (4,000 psi Concrete)
5,620 lb
Ultimate Tension Strength (4,000 psi Concrete)
3,765 lb
Allowable Tension in 2500 PSI Uncracked Concrete (Lbs.)
1539
Allowable Shear in 6500 PSI Cracked Concrete (Lbs.)
1670
Allowable Tension in 6500 PSI Cracked Concrete (Lbs.)
750
Allowable Tension in 2500 PSI Cracked Concrete (Lbs.)
484
Allowable Shear in 2500 PSI Uncracked Concrete (Lbs.)
1670
Allowable Shear in 2500 PSI Cracked Concrete (Lbs.)
1670
Allowable Shear in 6500 PSI Uncracked Concrete (Lbs.)
1670
Allowable Tension in 6500 PSI Uncracked Concrete (Lbs.)
1927
Thread Length
Not Applicable
ICC Approved for Un-Cracked Concrete
Yes
Industry Standards
ICC ESR-3173
Wedge Anchor Type
Seismic Wedge Anchor
Minimum Installation Torque
11 ft-lb
Material Grade/Class
Class 8.8
Minimum Ultimate Shear Strength
5,620 lb
Manufacturer Location
Made in USA
Washer Outside Diameter
18 mm
System of Measurement
Metric
Minimum Material Thickness
101 19/32 mm
Maximum Installation Torque
11 ft-lb
Minimum Ultimate Tension Strength
3,765 lb
Maximum Ultimate Tension Strength
21,444 lb
Material Quality Standards
ACI 318 Category 1
Maximum Ultimate Shear Strength
44,623 lb
Eyelet Hole Size
Not Applicable
Country of Origin (subject to change)
Germany