For Media
Hot Water, Steam
Valve Starting Configuration
Normally Closed
Inlet Connection Type
NPTF
Outlet Connection Type
NPTF
Valve Type
Diaphragm, Piston
Operation Type
Pilot Operated
Operating Pressure Differential - Maximum
150 psi Hot Water, 125 psi Steam
Operating Pressure Differential - Minimum
5 psi Hot Water, Steam
Center Line Pipe Center Size
4-3/4 in
Electrical Connections
1/2 in Conduit with 18 in Leads
Max. Fluid Temp. Hot Water
210 Degrees F
Coil Enclosure
Without Junction Box, Watertight
Max. Fluid Temp. Steam
353 Degrees F
Ambient Temp. Range
125 Degrees F
Application
Hot Water, Steam
Coefficient of Volume (Cv)
43
Operating Pressure Differential Water - Maximum
Not Rated
Operating Pressure Differential Cryogenic Fluid - Minimum
Not Applicable
Operating Pressure Differential Hot Water - Minimum
5 psi
Operating Pressure Differential Fuel Gas - Maximum
Not Applicable
Operating Pressure Differential Natural Gas - Minimum
Not Applicable
Operating Pressure Differential Air/Inert Gas - Minimum
Not Applicable
Fluid Temperature - Maximum
353°F Steam, 210°F Water
Operating Pressure Differential Fuel Oil - Maximum
Not Applicable
Operating Pressure Differential Light Oil - Minimum
Not Applicable
Valve Positions
2-Position
Operating Pressure Differential Air/Inert Gas - Maximum
Not Rated
Operating Pressure Differential Natural Gas - Maximum
Not Applicable
Environmental Rating
Hazardous, Indoor, Outdoor, Washdown
Operating Pressure Differential Fuel Gas - Minimum
Not Applicable
Operating Pressure Differential Fuel Oil - Minimum
Not Applicable
Operating Pressure Differential Liquid CO2 - Minimum
Not Applicable
Operating Pressure Differential Cryogenic Fluid - Maximum
Not Applicable
Ambient Temperature - Maximum
140 Degrees F
Operating Pressure Differential Steam - Maximum
125 psi
Operating Pressure Differential Light Oil - Maximum
Not Rated
Operating Pressure Differential Steam - Minimum
5 psi
Operating Pressure Differential Hot Water - Maximum
150 psi
NEMA Enclosure Rating
1, 2, 3, 3S, 4, 4X
Operating Pressure Differential Liquid CO2 - Maximum
Not Applicable
Ambient Temperature - Minimum
14 Degrees F
Country of Origin (subject to change)
Mexico